FT Series

FT Series

Electric Linear Actuator

  • Maximum force up to 40,000 lbf (177 kN)
  • Speeds up to 59.3 in/s (1500 mm/s)
  • Standard stroke lengths up to 48 in (1219 mm)
  • Sealed housing options for severe environments
  • Multiple models and sizes with planetary roller screw
Find a Distributor

Powerful Roller Screw Actuators Replace Hydraulics

The FT Series actuators from Exlar® use a planetary roller screw mounted inside an extruded aluminum housing. These electric linear actuators are compatible with a wide range of standard motors. Motor mounting and gearing configurations are available to meet the requirements of a wide variety of applications. The standard product is offered in four frame sizes with standard stroke lengths up to 36 inches (914 mm) and a load rating up to 40,000 lbf (177 kN).

Engineered Performance

As with all Exlar roller screw actuators, the FT Series delivers high load capacity, high speed, and exceptionally long life compared to acme and ball screw solutions. At equivalent sizes, under moderate to heavy loads, you can expect the FT Series to deliver up to 15 times the working life of other solutions. Greater power, exceptional durability and a much smaller footprint make the FT series a superior electric alternative to hydraulics.

Other Advantages

  • Flexible design suitable for a wide range of applications
  • Multiple frame sizes and an array of options to address almost any requirement
  • Compatible with a wide range of motors
  • Engineered solution accelerates integration and minimizes downtime
  • Designed for trouble-free operation in any environment

 

Quick Data

Models: FT35, FT45, FT60, FT80
Frame Sizes:  3.5, 4.8, 6.0, 8.0 in (89, 122, 152, 203 mm)
Stroke Lengths: 6, 12, 18, 24, 36, 48 (152, 305, 457, 610, 914, 1219 mm)
Linear Speed:  up to 60 in/sec (1524 mm/s)
Maximum Force: up to 40,000 lbf (178 kN)
Standards/Ratings:  IP65S

Related Industries

Configuration Options

FT Series Configuration Options

AA = Frame Size
BB = Stroke Length
CC = Screw Lead (linear travel per screw revolution)
D = Mounting
E = Motor Mounting Configurations
F = Rod End
GGG = Motor Mount Provisions

Mechanical Options

L1, L2, L3 = Adjustable External Travel Switch(es)

External travel switches indicate travel to the controller and are adjustable for either the home or end position.

XT = High Capacity Roller Screw

Note: The XT designation is used to specify several different special travel options. When ordering, it is important to describe, in detail, the specific XT option(s) that you need.

* Some options are not available with every configuration. For options or specials not listed above or for extended temperature operation, please consult Exlar Applications Engineering.

IP Ratings for Exlar Actuators

FT Series

FT35
Performance Specifications
 Printable View

FT35 Mechanical Specifications

    High Capacity Standard Capacity
    5 10 20 5 10 20
Screw Lead in 0.197 0.394 0.787 0.197 0.394 0.787
  mm 5 10 20 5 10 20
Maximum Force^1 lbf 5000 5000 5000 5000 5000 5000
  kN 22.2 22.2 22.2 22.2 22.2 22.2
Estimated L_10 Life at Maximum Force in x 10^6 15.4 24.6 56.7 8.88 14.15 32.05
  km 392 626 1440 225.6 359.4 814.2
C_a (Dynamic Load Rating) lbf 21400 19850 20800 17800 16500 17200
  kN 95.2 88.3 92.5 79.2 73.4 76.5
Maximum Input Torque lbf-in 196 392 783 196 392 783
  Nm 22.1 44.3 88.5 22.1 44.3 88.5
Max Rated RPM @ Input Shaft RPM 4500 4500 4500 4500 4500 4500
Maximum Linear Speed @ RPM Maximum Rated in/sec 14.7 29.5 59.3 14.7 29.5 59.3
  mm/sec 373 750 1500 373 750 1500

FT35 Inertias

  5 mm Lead 10 mm Lead 20 mm Lead  
NMT Unit - J (0) 0.0004087 0.0004121 0.0004259 kg-m² (at input shaft) kg-m²/inch of stroke
NMT Unit - J (Stroke) 0.0000159 0.0000162 0.0000171 kg-m² (at input shaft) kg-m²/inch of stroke
Inline w/ Coupler - J (0) 0.0005127 0.0005161 0.0005299 kg-m² (at motor shaft) kg-m²/inch of stroke
Inline w/ Coupler - J (Stroke) 0.0000159 0.0000162 0.0000171 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 1:1 - J (0) 0.0011042 0.0011855 0.001448 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 1:1 - J (Stroke) 0.0000159 0.0000162 0.0000171 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 2:1 - J (0) 0.0014029 0.0014038 0.0015345 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 2:1 - J (Stroke) 0.0000040 0.0000040 0.0000043 kg-m² (at motor shaft) kg-m²/inch of stroke
         
Standard Inline Coupling Inertia 0.000104 kg-m² (0.000920 lbf-in s²)

FT35 Weights

Base Actuator Weight lb kg
6 Inch Stroke Length 30 14
12 Inch Stroke Length 35 16
18 Inch Stroke Length 40 18
24 Inch Stroke Length 45 21
36 Inch Stroke Length 55 25
48 Inch Stroke Length 65 30
Adder for Inline (excluding motor) 8 3.6
Adder for Parallel Drive (excluding motor) 16 7.3
Adder for Front Flange 5.4 2.5
Adder for Rear Flange 7.4 3.4
Adder for Rear Clevis 3 1.4
Adder for Rear Eye NA NA
Adder for Front/Rear Angle Mounts NA NA
Adder for Two Trunnions 19.5 8.9
Adder for Two Foot Mounts 3.3 1.5
Data Curves
Estimated Life Time Curves
Ordering Guide
 Printable View

To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

 

FT Order

 

Product Selection Guidelines

To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

AA = Frame Size

35 = 3.5 inch (90 mm)
45 = 4.8 inch (122 mm)
60 = 6.4 inch (162 mm)
80 = 8.5 inch (216 mm)

BB = Stroke Length

06 = 6 inch (152 mm) FT35
12 = 12 inch (305 mm) FT35, 45, 60, 80
18 =18 inch (457 mm) FT35, 45
24 = 24 inch (610 mm) FT35, 45, 60, 80
36 = 36 inch (914 mm) FT35, 45, 60, 80
48 = 48 inch (1219 mm) FT35, 45, 60, 80

CC= Screw Lead

05 = 0.2 inch, FT35, 45
06 = 0.23 inch, FT60, 80
10 = 0.39 inch, FT35, 45
12 = 0.47 inch, FT60, 80
20 = 0.79 inch, FT35
30 = 1.18 inch, FT60, 80

D = Mounting Style

N = None
F = Front flange, English
Z = Front flange, Metric, FT45
R = Rear flange, English (1,2)
C = Rear clevis, English (1,2)
G = Rear clevis, Metric (1,2)
Y = Rear eye, English (1), FT45
W = Rear eye, Metric (1), FT45
L = Side lugs
S = Side mount, English, FT35, 60, 80
J = Side mount, Metric, FT35, 60, 80
T = Side trunnion mount, English (2,3), FT35, 60, 80
Q = Side trunnion mount, Metric (2,3), FT35, 60, 80
2 = Rear trunnion mount, English, FT45
P = Rear trunnion mount, Metric, FT45
E = Extended tie rods, English
M = Extended tie rods, Metric

Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with your local sales representative.

  1. Not available with inline motor mount, contact your local sales representative.
  2. Application details must be discussed for an FT80
  3. IP65 environmental sealing option not available
E= Motor Mounting Configurations

N = None
I = Inline direct drive (includes Exlar standard coupling)
P = Parallel, 1:1 belt reduction
Q = Parallel, 2:1 belt reduction

Maximum Standard Motor Size
FT35: 5.6 inch/165 mm
FT45: 7.1 inch/215 mm
FT60: 7.9 inch/215 mm
FT80: 8.5 inch/300 mm

For oversized motors, contact your local sales representative.

F= Rod End

M= Male, US std. thread
A= Male, metric thread
F= Female, US std. thread
B= Female, metric thread

GGG = Motor Mount Provisions

FT35 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
68 60 12 30 4 GFB
68 60 16 48 5 GFA
70 50 14 30 5 JGA
70 50 16 30 5 GGB
70 50 16 36 5 EGB
70 50 16 40 5 GGA
75 60 14 30 5 IHB
75 60 16 32 5 GHB
75 60 16 48 5 GHA
85 70 16 37 5 GIB
85 70 22 56 6 GIA
90 60 19 40 6 JKF
90 70 14 30 5 JKD
90 70 16 35 NA JKC
90 70 16 40 5 JKG
90 70 19 40 6 JKA
95 50 14 30 5 ELC
95 65 14 30 5 ELA
95 65 16 30 5 ELB
100 50 16 31 6 GMC
100 80 14 30 5 IMA

FT45 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
85 70 22 49 6 GIA
95 65 16 30 5 ELB
100 50 16 31 6 GMC
100 80 14 30 5 IMA
100 80 14 40 5 JMC
100 80 16 40 5 IMB
100 80 19 40 6 IMC
100 80 19 55 6 JMD
100 80 20 40 6 GMB
100 80 22 52 6 GMA
115 95 19 40 6 INA
115 95 19 55 6 JNC
115 95 22 45 8 JND
115 95 22 70 NA JNB
115 95 24 45 8 JNA
115 95 24 50 8 INB
120 60 22 39 6 G7C
120 90 22 46 6 G7B
120 90 32 88 10 G7A
120 100 32 85 10 G7D
130 95 19 40 6 IPC
130 95 24 50 8 IPD
130 110 19 40 6 IPA
130 110 24 50 8 IPB
140 110 32 64 10 E5A
145 110 19 55 5 JQG

FT60 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
100 50 16 31 6 GMC
100 80 20 40 6 GMB
100 80 22 48 6 GMA
115 95 19 40 6 INA
115 95 19 55 6 JNC
115 95 22 45 8 JND
115 95 22 70 NA JNB
115 95 24 45 8 JNA
115 95 24 50 8 INB
120 60 22 39 6 G7C
120 90 22 46 6 G7B
120 90 32 88 10 G7A
120 100 32 85 10 G7D
120 130 40 112 12 G7E
130 95 19 40 6 IPC
130 95 24 50 8 IPD
130 110 19 40 6 IPA
130 110 24 50 8 GPC
130 110 24 50 8 IPB
130 110 25 55 8 GPB
130 110 32 65 10 GPA
140 110 32 64 10 E5A
145 110 19 55 5 JQG
145 110 19 55 6 JQK
145 110 22 55 8 JQH
145 110 22 55 6 JQF
145 110 22 70 8 JQE
145 110 24 58 8 JQD
145 110 24 65 8 JQC

FT80 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
130 110 24 50 8 GPC
130 110 25 55 8 GPB
130 110 32 72 10 GPA
165 80 32 63 10 GRE
165 95 24 50 8 IRG
165 110 24 50 8 IRF
165 130 24 50 8 IRA
165 130 28 60 8 IRB
165 130 32 50 10 IRD
165 130 32 58 10 IRC
165 130 32 72 10 GRD
165 130 32 80 10 IRE
165 130 40 80 12 GRB
165 130 40 102 12 GRC
165 130 40 112 12 GRA
190 155 32 60 10 I2A
200 114.3 28 55 8 JSF
200 114.3 35 70 10 JSB
200 114.3 35 80 10 JSA
200 114.3 42 113 10 JSD
200 114.3 42 113 12 JSG
215 130 32 60 10 ITE
MM = Mechanical Options

Limit Switches

FT35, FT60, FT80

Option Quantity Part Number Description
L1 1 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L2 2 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L3 3 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L4     N/A
L5     N/A
L6     N/A

FT45

Option Quantity Part Number Description
L1 1 43403 Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L2 2 43404 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L3 1
2
43403
43404
Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L4 1 67634 Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L5 2 67635 Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L6 1
2
67634
67635
Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
FT45
Performance Specifications
 Printable View

FT45 Mechanical Specifications

    High Capacity Standard Capacity
    5 10 5 10
Screw Lead in 0.197 0.394 0.197 0.394
  mm 5 10 5 10
Maximum Force* lbf 10000 10000 10000 10000
  kN 44.5 44.5 44.5 44.5
Estimated L_10 Life at Maximum Force in x 10^6 9.81 19.14 5.67 11.06
  km 249.2 486.3 144 280.9
C_a (Dynamic Load Rating) lbf 36800 36500 30650 30400
  kN 163.7 162.4 136.3 135.2
Maximum Input Torque lbf-in 392 783 392 783
  Nm 44.1 88.2 44.1 88.2
Max Rated RPM @ Input Shaft RPM 3500 3500 3500 3500
Maximum Linear Speed @ Maximum Rated RPM in/sec 11.5 23 11.5 23
  mm/sec 292 583 292 583

*Maximum allowable actuator-generated force that can be applied routinely. Exceeding this force may result in permanent damage to the actuator. For high force, short stroke applications, consult factory.

FT45 Inertias

  5 mm Lead 10 mm Lead  
NMT Unit - J (0) 0.002463 0.002474 kg-m² (at input shaft) kg-m²/inch of stroke
NMT Unit - J (Stroke) 0.000045 0.000046 kg-m² (at input shaft) kg-m²/inch of stroke
Inline w/ Coupler - J (0) 0.002571 0.002581 kg-m² (at motor shaft) kg-m²/inch of stroke
Inline w/ Coupler - J (Stroke) 0.000045 0.000046 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 1:1 - J (0) 0.006911 0.006921 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 1:1 - J (Stroke) 0.000045 0.000046 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 2:1 - J (0) 0.003466 0.003469 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 2:1 - J (Stroke) 0.000011 0.000011 kg-m² (at motor shaft) kg-m²/inch of stroke
       
Standard Inline Coupling Inertia 0.00010743 kg-m² (0.000951 lbf-in s²)

*Pulleys for parallel mount match actuator max performance ratings. Pulley inertias reflected at motor including typical pulleys, belt and standard bushings. Because of differences in belt and pulley selection due to particular motor choices, please contact your local sales representative if these values are critical to your application.

FT45 Weights

Base Actuator Weight lb kg
6 Inch Stroke Length 57 26
12 Inch Stroke Length 68 31
18 Inch Stroke Length 79 36
24 Inch Stroke Length 90 41
36 Inch Stroke Length 112 51
48 Inch Stroke Length 135 61
Adder for Inline (excluding motor) 7.1 3.2
Adder for Parallel Drive (excluding motor) 42.5 19.3
Adder for Front Flange 6.1 2.8
Adder for Rear Flange 17.4 7.9
Adder for Rear Clevis 18.9 8.6
Adder for Rear Eye 19.8 9
Adder for Front/Rear Angle Mounts NA NA
Adder for Two Trunnions 17.2 7.8
Adder for Two Foot Mounts 10.4 4.7
Data Curves
Estimated Life Time Curves
Ordering Guide
 Printable View

To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

 

FT Order

 

Product Selection Guidelines

To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

AA = Frame Size

35 = 3.5 inch (90 mm)
45 = 4.8 inch (122 mm)
60 = 6.4 inch (162 mm)
80 = 8.5 inch (216 mm)

BB = Stroke Length

06 = 6 inch (152 mm) FT35
12 = 12 inch (305 mm) FT35, 45, 60, 80
18 =18 inch (457 mm) FT35, 45
24 = 24 inch (610 mm) FT35, 45, 60, 80
36 = 36 inch (914 mm) FT35, 45, 60, 80
48 = 48 inch (1219 mm) FT35, 45, 60, 80

CC= Screw Lead

05 = 0.2 inch, FT35, 45
06 = 0.23 inch, FT60, 80
10 = 0.39 inch, FT35, 45
12 = 0.47 inch, FT60, 80
20 = 0.79 inch, FT35
30 = 1.18 inch, FT60, 80

D = Mounting Style

N = None
F = Front flange, English
Z = Front flange, Metric, FT45
R = Rear flange, English (1,2)
C = Rear clevis, English (1,2)
G = Rear clevis, Metric (1,2)
Y = Rear eye, English (1), FT45
W = Rear eye, Metric (1), FT45
L = Side lugs
S = Side mount, English, FT35, 60, 80
J = Side mount, Metric, FT35, 60, 80
T = Side trunnion mount, English (2,3), FT35, 60, 80
Q = Side trunnion mount, Metric (2,3), FT35, 60, 80
2 = Rear trunnion mount, English, FT45
P = Rear trunnion mount, Metric, FT45
E = Extended tie rods, English
M = Extended tie rods, Metric

Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with your local sales representative.

  1. Not available with inline motor mount, contact your local sales representative.
  2. Application details must be discussed for an FT80
  3. IP65 environmental sealing option not available
E= Motor Mounting Configurations

N = None
I = Inline direct drive (includes Exlar standard coupling)
P = Parallel, 1:1 belt reduction
Q = Parallel, 2:1 belt reduction

Maximum Standard Motor Size
FT35: 5.6 inch/165 mm
FT45: 7.1 inch/215 mm
FT60: 7.9 inch/215 mm
FT80: 8.5 inch/300 mm

For oversized motors, contact your local sales representative.

F= Rod End

M= Male, US std. thread
A= Male, metric thread
F= Female, US std. thread
B= Female, metric thread

GGG = Motor Mount Provisions

FT35 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
68 60 12 30 4 GFB
68 60 16 48 5 GFA
70 50 14 30 5 JGA
70 50 16 30 5 GGB
70 50 16 36 5 EGB
70 50 16 40 5 GGA
75 60 14 30 5 IHB
75 60 16 32 5 GHB
75 60 16 48 5 GHA
85 70 16 37 5 GIB
85 70 22 56 6 GIA
90 60 19 40 6 JKF
90 70 14 30 5 JKD
90 70 16 35 NA JKC
90 70 16 40 5 JKG
90 70 19 40 6 JKA
95 50 14 30 5 ELC
95 65 14 30 5 ELA
95 65 16 30 5 ELB
100 50 16 31 6 GMC
100 80 14 30 5 IMA

FT45 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
85 70 22 49 6 GIA
95 65 16 30 5 ELB
100 50 16 31 6 GMC
100 80 14 30 5 IMA
100 80 14 40 5 JMC
100 80 16 40 5 IMB
100 80 19 40 6 IMC
100 80 19 55 6 JMD
100 80 20 40 6 GMB
100 80 22 52 6 GMA
115 95 19 40 6 INA
115 95 19 55 6 JNC
115 95 22 45 8 JND
115 95 22 70 NA JNB
115 95 24 45 8 JNA
115 95 24 50 8 INB
120 60 22 39 6 G7C
120 90 22 46 6 G7B
120 90 32 88 10 G7A
120 100 32 85 10 G7D
130 95 19 40 6 IPC
130 95 24 50 8 IPD
130 110 19 40 6 IPA
130 110 24 50 8 IPB
140 110 32 64 10 E5A
145 110 19 55 5 JQG

FT60 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
100 50 16 31 6 GMC
100 80 20 40 6 GMB
100 80 22 48 6 GMA
115 95 19 40 6 INA
115 95 19 55 6 JNC
115 95 22 45 8 JND
115 95 22 70 NA JNB
115 95 24 45 8 JNA
115 95 24 50 8 INB
120 60 22 39 6 G7C
120 90 22 46 6 G7B
120 90 32 88 10 G7A
120 100 32 85 10 G7D
120 130 40 112 12 G7E
130 95 19 40 6 IPC
130 95 24 50 8 IPD
130 110 19 40 6 IPA
130 110 24 50 8 GPC
130 110 24 50 8 IPB
130 110 25 55 8 GPB
130 110 32 65 10 GPA
140 110 32 64 10 E5A
145 110 19 55 5 JQG
145 110 19 55 6 JQK
145 110 22 55 8 JQH
145 110 22 55 6 JQF
145 110 22 70 8 JQE
145 110 24 58 8 JQD
145 110 24 65 8 JQC

FT80 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
130 110 24 50 8 GPC
130 110 25 55 8 GPB
130 110 32 72 10 GPA
165 80 32 63 10 GRE
165 95 24 50 8 IRG
165 110 24 50 8 IRF
165 130 24 50 8 IRA
165 130 28 60 8 IRB
165 130 32 50 10 IRD
165 130 32 58 10 IRC
165 130 32 72 10 GRD
165 130 32 80 10 IRE
165 130 40 80 12 GRB
165 130 40 102 12 GRC
165 130 40 112 12 GRA
190 155 32 60 10 I2A
200 114.3 28 55 8 JSF
200 114.3 35 70 10 JSB
200 114.3 35 80 10 JSA
200 114.3 42 113 10 JSD
200 114.3 42 113 12 JSG
215 130 32 60 10 ITE
MM = Mechanical Options

Limit Switches

FT35, FT60, FT80

Option Quantity Part Number Description
L1 1 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L2 2 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L3 3 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L4     N/A
L5     N/A
L6     N/A

FT45

Option Quantity Part Number Description
L1 1 43403 Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L2 2 43404 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L3 1
2
43403
43404
Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L4 1 67634 Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L5 2 67635 Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L6 1
2
67634
67635
Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
FT60
Performance Specifications
 Printable View

FT60 Mechanical Specifications

    High Capacity Standard Capacity
    6 12 30 6 12 30
Screw Lead in 0.236 0.472 1.181 0.236 0.472 1.181
  mm 6 12 30 6 12 30
Maximum Force ^1 lbf 20000 20000 20000 20000 20000 20000
  kN 89 89 89 89 89 89
Estimated L_10 Life at Maximum Force in x 10^6 5.7 7.3 38.6 4.1 5.2 10.7
  km 145.8 184.7 981.1 104.8 133.1 271.9
C_a (Dynamic Load Rating) lbf 57933 49750 63958 51900 44600 41700
  kN 257.7 221.3 284.5 230.9 198.4 185.5
Maximum Input Torque lbf-in 940 1880 4699 940 1880 4699
  Nm 106 212 531 106 212 531
Max Rated RPM @ Input Shaft RPM 2000 2000 2000 2000 2000 2000
Maximum Linear Speed @ Maximum Rated RPM in/sec 7.9 15.8 39 7.9 15.8 39
  mm/sec 201 401 1000 201 401 1000

1 -Maximum allowable actuator-generated force that can be applied routinely. Exceeding this force may result in permanent damage to the actuator. For high force, short stroke applications, consult factory.

FT60 Inertias

  6 mm Lead 12 mm Lead 30 mm Lead  
NMT Unit - J (0) 0.0078464 0.0078709 0.0080424 kg-m² (at input shaft) kg-m²/inch of stroke
NMT Unit - J (Stroke) 0.0002539 0.0002547 0.00026 kg-m² (at input shaft) kg-m²/inch of stroke
Inline w/ Coupler - J (0) 0.0081764 0.0082009 0.0083724 kg-m² (at motor shaft) kg-m²/inch of stroke
Inline w/ Coupler - J (Stroke) 0.0002539 0.0002547 0.00026 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 1:1 - J (0) 0.0129357 0.0146113 0.0312682 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 1:1 - J (Stroke) 0.0002539 0.0002547 0.00026 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 2:1 - J (0) 0.0049158 0.0057202 0.0214777 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 2:1 - J (Stroke) 0.0000635 0.0000637 0.0000650 kg-m² (at motor shaft) kg-m²/inch of stroke
         
Standard Inline Coupling Inertia 0.000330 kg-m² (0.002921 lbf-in s²)

*Pulleys for parallel mount match actuator max performance ratings. Pulley inertias reflected at motor including typical pulleys, belt and standard bushings. Because of differences in belt and pulley selection due to particular motor choices, please contact your local sales representative if these values are critical to your application.

FT60 Weights

Base Actuator Weight lb kg
12 inch Stroke Length 100 45
24 inch Stroke Length 130 59
36 Inch Stroke Length 160 72
48 Inch Stroke Length 190 86
Adder for Inline (excluding motor) 20.4 9.3
Adder for Parallel Drive (excluding motor) 39.1 17.7
Adder for Front Flange 13.4 6.1
Adder for Rear Flange 15.9 7.2
Adder for Rear Clevis 11.1 5
Adder for Rear Eye NA NA
Adder for Front/Rear Angle Mounts NA NA
Adder for Two Trunnions 44.3 20.1
Adder for Two Foot Mounts 10.4 4.7
Data Curves
Estimated Life Time Curves
Ordering Guide
 Printable View

To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

FT Order

Product Selection Guidelines

To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

AA = Frame Size

35 = 3.5 inch (90 mm)
45 = 4.8 inch (122 mm)
60 = 6.4 inch (162 mm)
80 = 8.5 inch (216 mm)

BB = Stroke Length

06 = 6 inch (152 mm) FT35
12 = 12 inch (305 mm) FT35, 45, 60, 80
18 =18 inch (457 mm) FT35, 45
24 = 24 inch (610 mm) FT35, 45, 60, 80
36 = 36 inch (914 mm) FT35, 45, 60, 80
48 = 48 inch (1219 mm) FT35, 45, 60, 80

CC= Screw Lead

05 = 0.2 inch, FT35, 45
06 = 0.23 inch, FT60, 80
10 = 0.39 inch, FT35, 45
12 = 0.47 inch, FT60, 80
20 = 0.79 inch, FT35
30 = 1.18 inch, FT60, 80

D = Mounting Style

N = None
F = Front flange, English
Z = Front flange, Metric, FT45
R = Rear flange, English (1,2)
C = Rear clevis, English (1,2)
G = Rear clevis, Metric (1,2)
Y = Rear eye, English (1), FT45
W = Rear eye, Metric (1), FT45
L = Side lugs
S = Side mount, English, FT35, 60, 80
J = Side mount, Metric, FT35, 60, 80
T = Side trunnion mount, English (2,3), FT35, 60, 80
Q = Side trunnion mount, Metric (2,3), FT35, 60, 80
2 = Rear trunnion mount, English, FT45
P = Rear trunnion mount, Metric, FT45
E = Extended tie rods, English
M = Extended tie rods, Metric

Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with your local sales representative.

  1. Not available with inline motor mount, contact your local sales representative.
  2. Application details must be discussed for an FT80
  3. IP65 environmental sealing option not available
E= Motor Mounting Configurations

N = None
I = Inline direct drive (includes Exlar standard coupling)
P = Parallel, 1:1 belt reduction
Q = Parallel, 2:1 belt reduction

Maximum Standard Motor Size
FT35: 5.6 inch/165 mm
FT45: 7.1 inch/215 mm
FT60: 7.9 inch/215 mm
FT80: 8.5 inch/300 mm

For oversized motors, contact your local sales representative.

F= Rod End

M= Male, US std. thread
A= Male, metric thread
F= Female, US std. thread
B= Female, metric thread

GGG = Motor Mount Provisions

FT35 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
68 60 12 30 4 GFB
68 60 16 48 5 GFA
70 50 14 30 5 JGA
70 50 16 30 5 GGB
70 50 16 36 5 EGB
70 50 16 40 5 GGA
75 60 14 30 5 IHB
75 60 16 32 5 GHB
75 60 16 48 5 GHA
85 70 16 37 5 GIB
85 70 22 56 6 GIA
90 60 19 40 6 JKF
90 70 14 30 5 JKD
90 70 16 35 NA JKC
90 70 16 40 5 JKG
90 70 19 40 6 JKA
95 50 14 30 5 ELC
95 65 14 30 5 ELA
95 65 16 30 5 ELB
100 50 16 31 6 GMC
100 80 14 30 5 IMA

 

FT45 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
85 70 22 49 6 GIA
95 65 16 30 5 ELB
100 50 16 31 6 GMC
100 80 14 30 5 IMA
100 80 14 40 5 JMC
100 80 16 40 5 IMB
100 80 19 40 6 IMC
100 80 19 55 6 JMD
100 80 20 40 6 GMB
100 80 22 52 6 GMA
115 95 19 40 6 INA
115 95 19 55 6 JNC
115 95 22 45 8 JND
115 95 22 70 NA JNB
115 95 24 45 8 JNA
115 95 24 50 8 INB
120 60 22 39 6 G7C
120 90 22 46 6 G7B
120 90 32 88 10 G7A
120 100 32 85 10 G7D
130 95 19 40 6 IPC
130 95 24 50 8 IPD
130 110 19 40 6 IPA
130 110 24 50 8 IPB
140 110 32 64 10 E5A
145 110 19 55 5 JQG

 

FT60 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
100 50 16 31 6 GMC
100 80 20 40 6 GMB
100 80 22 48 6 GMA
115 95 19 40 6 INA
115 95 19 55 6 JNC
115 95 22 45 8 JND
115 95 22 70 NA JNB
115 95 24 45 8 JNA
115 95 24 50 8 INB
120 60 22 39 6 G7C
120 90 22 46 6 G7B
120 90 32 88 10 G7A
120 100 32 85 10 G7D
120 130 40 112 12 G7E
130 95 19 40 6 IPC
130 95 24 50 8 IPD
130 110 19 40 6 IPA
130 110 24 50 8 GPC
130 110 24 50 8 IPB
130 110 25 55 8 GPB
130 110 32 65 10 GPA
140 110 32 64 10 E5A
145 110 19 55 5 JQG
145 110 19 55 6 JQK
145 110 22 55 8 JQH
145 110 22 55 6 JQF
145 110 22 70 8 JQE
145 110 24 58 8 JQD
145 110 24 65 8 JQC

 

FT80 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
130 110 24 50 8 GPC
130 110 25 55 8 GPB
130 110 32 72 10 GPA
165 80 32 63 10 GRE
165 95 24 50 8 IRG
165 110 24 50 8 IRF
165 130 24 50 8 IRA
165 130 28 60 8 IRB
165 130 32 50 10 IRD
165 130 32 58 10 IRC
165 130 32 72 10 GRD
165 130 32 80 10 IRE
165 130 40 80 12 GRB
165 130 40 102 12 GRC
165 130 40 112 12 GRA
190 155 32 60 10 I2A
200 114.3 28 55 8 JSF
200 114.3 35 70 10 JSB
200 114.3 35 80 10 JSA
200 114.3 42 113 10 JSD
200 114.3 42 113 12 JSG
215 130 32 60 10 ITE
MM = Mechanical Options

Limit Switches

FT35, FT60, FT80

Option Quantity Part Number Description
L1 1 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L2 2 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L3 3 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L4     N/A
L5     N/A
L6     N/A

FT45

Option Quantity Part Number Description
L1 1 43403 Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L2 2 43404 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L3 1
2
43403
43404
Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L4 1 67634 Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L5 2 67635 Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L6 1
2
67634
67635
Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
FT80
Performance Specifications
 Printable View

FT80 Mechanical Specifications

    High Capacity Standard Capacity
    6 12 30 6 12 30
Screw Lead in 0.236 0.472 1.181 0.236 0.472 1.181
  mm 6 12 30 6 12 30
Maximum Force^1 lbf 40000 40000 40000 40000 40000 40000
  kN 177.9 177.9 177.9 177.9 177.9 177.9
Estimated L_10 Life at Maximum Force in x 10^6 3.1 4.4 16.3 1.94 2.55 5
  km 78.7 111.4 414.3 49.3 64.9 127
C_a (Dynamic Load Rating) lbf 94330 84079 95971 80700 70200 64700
  kN 419.6 374 426.9 359 312.2 287.8
Maximum Input Torque lbf-in 1880 3760 9399 1880 3760 9399
  Nm 212 425 1062 212 425 1062
Max Rated RPM @ Input Shaft RPM 1750 1750 1750 1750 1750 1750
Maximum Linear Speed @ Maximum Rated RPM in/sec 6.9 13.8 34.4 6.9 13.8 34.4
  mm/sec 175 351 875 175 351 875

1- Maximum allowable actuator-generated force that can be applied routinely. Exceeding this force may result in permanent damage to the actuator. For high force, short stroke applications, consult factory.

FT80 Inertias

  6 mm Lead 12 mm Lead 30 mm Lead  
NMT Unit - J (0) 0.0302504 0.0303275 0.0308673 kg-m² (at input shaft) kg-m²/inch of stroke
NMT Unit - J (Stroke) 0.0008022 0.0008035 0.0008124 kg-m² (at input shaft) kg-m²/inch of stroke
Inline w/ Coupler - J (0) 0.0314604 0.0315375 0.0320773 kg-m² (at motor shaft) kg-m²/inch of stroke
Inline w/ Coupler - J (Stroke) 0.0008022 0.0008035 0.0008124 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 1:1 - J (0) 0.0721056 0.0535533 0.1342578 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 1:1 - J (Stroke) 0.0008022 0.0008035 0.0008124 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 2:1 - J (0) 0.0198765 0.027049 0.0753395 kg-m² (at motor shaft) kg-m²/inch of stroke
Parallel 2:1 - J (Stroke) 0.0002006 0.0002009 0.0002031 kg-m² (at motor shaft) kg-m²/inch of stroke
         
Standard Inline Coupling Inertia 0.0001210 kg-m² (0.010709 lbf-in s²)

*Pulleys for parallel mount match actuator max performance ratings. Pulley inertias reflected at motor including typical pulleys, belt and standard bushings. Because of differences in belt and pulley selection due to particular motor choices, please contact your local sales representative if these values are critical to your application.

FT80 Weights

Base Actuator Weight lb kg
12 Inch Stroke Length 190 86
24 Inch Stroke Length 265 120
36 Inch Stroke Length 340 153
48 Inch Stroke Length 415 187
Adder for Inline (excluding motor) 54.9 24.9
Adder for Parallel Drive (excluding motor) 79.1 35.9
Adder for Front Flange 28.5 17.5
Adder for Rear Flange NA NA
Adder for Rear Clevis NA NA
Adder for Rear Eye NA NA
Adder for Front/Rear Angle Mounts NA NA
Adder for Two Trunnions NA NA
Adder for Two Foot Mounts 34.8 15.8
Data Curves
Estimated Life Time Curves
Ordering Guide
 Printable View

To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

 

FT Order

 

Product Selection Guidelines

To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

AA = Frame Size

35 = 3.5 inch (90 mm)
45 = 4.8 inch (122 mm)
60 = 6.4 inch (162 mm)
80 = 8.5 inch (216 mm)

BB = Stroke Length

06 = 6 inch (152 mm) FT35
12 = 12 inch (305 mm) FT35, 45, 60, 80
18 =18 inch (457 mm) FT35, 45
24 = 24 inch (610 mm) FT35, 45, 60, 80
36 = 36 inch (914 mm) FT35, 45, 60, 80
48 = 48 inch (1219 mm) FT35, 45, 60, 80

CC= Screw Lead

05 = 0.2 inch, FT35, 45
06 = 0.23 inch, FT60, 80
10 = 0.39 inch, FT35, 45
12 = 0.47 inch, FT60, 80
20 = 0.79 inch, FT35
30 = 1.18 inch, FT60, 80

D = Mounting Style

N = None
F = Front flange, English
Z = Front flange, Metric, FT45
R = Rear flange, English (1,2)
C = Rear clevis, English (1,2)
G = Rear clevis, Metric (1,2)
Y = Rear eye, English (1), FT45
W = Rear eye, Metric (1), FT45
L = Side lugs
S = Side mount, English, FT35, 60, 80
J = Side mount, Metric, FT35, 60, 80
T = Side trunnion mount, English (2,3), FT35, 60, 80
Q = Side trunnion mount, Metric (2,3), FT35, 60, 80
2 = Rear trunnion mount, English, FT45
P = Rear trunnion mount, Metric, FT45
E = Extended tie rods, English
M = Extended tie rods, Metric

Mounting face size, shaft length and other details of particular motors may require special adapters or provisions for mounting. Always discuss your motor selection with your local sales representative.

  1. Not available with inline motor mount, contact your local sales representative.
  2. Application details must be discussed for an FT80
  3. IP65 environmental sealing option not available
E= Motor Mounting Configurations

N = None
I = Inline direct drive (includes Exlar standard coupling)
P = Parallel, 1:1 belt reduction
Q = Parallel, 2:1 belt reduction

Maximum Standard Motor Size
FT35: 5.6 inch/165 mm
FT45: 7.1 inch/215 mm
FT60: 7.9 inch/215 mm
FT80: 8.5 inch/300 mm

For oversized motors, contact your local sales representative.

F= Rod End

M= Male, US std. thread
A= Male, metric thread
F= Female, US std. thread
B= Female, metric thread

GGG = Motor Mount Provisions

FT35 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
68 60 12 30 4 GFB
68 60 16 48 5 GFA
70 50 14 30 5 JGA
70 50 16 30 5 GGB
70 50 16 36 5 EGB
70 50 16 40 5 GGA
75 60 14 30 5 IHB
75 60 16 32 5 GHB
75 60 16 48 5 GHA
85 70 16 37 5 GIB
85 70 22 56 6 GIA
90 60 19 40 6 JKF
90 70 14 30 5 JKD
90 70 16 35 NA JKC
90 70 16 40 5 JKG
90 70 19 40 6 JKA
95 50 14 30 5 ELC
95 65 14 30 5 ELA
95 65 16 30 5 ELB
100 50 16 31 6 GMC
100 80 14 30 5 IMA

 

FT45 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
85 70 22 49 6 GIA
95 65 16 30 5 ELB
100 50 16 31 6 GMC
100 80 14 30 5 IMA
100 80 14 40 5 JMC
100 80 16 40 5 IMB
100 80 19 40 6 IMC
100 80 19 55 6 JMD
100 80 20 40 6 GMB
100 80 22 52 6 GMA
115 95 19 40 6 INA
115 95 19 55 6 JNC
115 95 22 45 8 JND
115 95 22 70 NA JNB
115 95 24 45 8 JNA
115 95 24 50 8 INB
120 60 22 39 6 G7C
120 90 22 46 6 G7B
120 90 32 88 10 G7A
120 100 32 85 10 G7D
130 95 19 40 6 IPC
130 95 24 50 8 IPD
130 110 19 40 6 IPA
130 110 24 50 8 IPB
140 110 32 64 10 E5A
145 110 19 55 5 JQG

 

FT60 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
100 50 16 31 6 GMC
100 80 20 40 6 GMB
100 80 22 48 6 GMA
115 95 19 40 6 INA
115 95 19 55 6 JNC
115 95 22 45 8 JND
115 95 22 70 NA JNB
115 95 24 45 8 JNA
115 95 24 50 8 INB
120 60 22 39 6 G7C
120 90 22 46 6 G7B
120 90 32 88 10 G7A
120 100 32 85 10 G7D
120 130 40 112 12 G7E
130 95 19 40 6 IPC
130 95 24 50 8 IPD
130 110 19 40 6 IPA
130 110 24 50 8 GPC
130 110 24 50 8 IPB
130 110 25 55 8 GPB
130 110 32 65 10 GPA
140 110 32 64 10 E5A
145 110 19 55 5 JQG
145 110 19 55 6 JQK
145 110 22 55 8 JQH
145 110 22 55 6 JQF
145 110 22 70 8 JQE
145 110 24 58 8 JQD
145 110 24 65 8 JQC

 

FT80 Motor Mount Codes

Bolt Circle Diameter (mm) Pilot Diameter (mm) Shaft Diameter (mm) Shaft Length (mm) Key Width (mm) Motor Mount Code
130 110 24 50 8 GPC
130 110 25 55 8 GPB
130 110 32 72 10 GPA
165 80 32 63 10 GRE
165 95 24 50 8 IRG
165 110 24 50 8 IRF
165 130 24 50 8 IRA
165 130 28 60 8 IRB
165 130 32 50 10 IRD
165 130 32 58 10 IRC
165 130 32 72 10 GRD
165 130 32 80 10 IRE
165 130 40 80 12 GRB
165 130 40 102 12 GRC
165 130 40 112 12 GRA
190 155 32 60 10 I2A
200 114.3 28 55 8 JSF
200 114.3 35 70 10 JSB
200 114.3 35 80 10 JSA
200 114.3 42 113 10 JSD
200 114.3 42 113 12 JSG
215 130 32 60 10 ITE
MM = Mechanical Options

Limit Switches

FT35, FT60, FT80

Option Quantity Part Number Description
L1 1 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L2 2 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L3 3 14453 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L4     N/A
L5     N/A
L6     N/A

FT45

Option Quantity Part Number Description
L1 1 43403 Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L2 2 43404 Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L3 1
2
43403
43404
Normally Open PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
Normally Closed PNP Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L4 1 67634 Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L5 2 67635 Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
L6 1
2
67634
67635
Normally Open NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)
Normally Closed NPN Limit Switch (10-30 VDC, 1m. 3 wire embedded cable)

Resources

Certifications

See All Resource Material for the Tritex II and other products in our Resource Library

Login

Please log in or register to see the models and drawings.

Register

If you do not have a login, please proceed to the registration page

Register

If you currently have an Exlar website account and would like to delete it, please contact

CHA_Info@curtiss-wright.com

Privacy Notice

By giving us your contact information, you are giving consent to Curtiss-Wright / Exlar Automation to store your data and follow-up with you via email or phone.

At Curtiss-Wright, we promise to treat your data with respect and only share it with our representatives and distributors for the purpose outlined on the form. You can remove your request or information at any time by reaching out to our team at cha_info@curtisswright.com.

For further information on how we protect your information, please refer to our Privacy Notice.


Stay up to date

Get the latest Exlar product updates delivered directly to your inbox

You can change your mind at any time by clicking the unsubscribe link in the footer of any email you receive from us, or by contacting us at cha_info@curtisswright.com



Country *:
 Security code
 How we use this information