Tritex II® AC Linear Actuator

Tritex II® AC Linear Actuator

Fully Integrated Drive/Motor/Actuator

  • Continuous force up to 3,225 lbf (14 kN)
  • Speeds up to 33 in/s (800 mm/s)
  • Strokes from 3 to 18 in (75 to 450 mm)
  • Voltage ratings from 100 - 240 VRMS
  • Complete stand-alone solution
Find a Distributor

Industry-Leading All-in-One AC Powered Actuator

By combining the latest electronic power technology with advanced thermal management modeling technology, Exlar has set a new benchmark for performance and size. Tritex II Series actuators integrate an AC powered servo drive, digital position controller, brushless motor and linear actuator in a compact, sealed package. Now you can precisely control motion and solve all of your application requirements with a single, fully integrated device. Simply connect AC power, I/O and communications; and it’s ready to go!

Dramatically Increase Performance

Tritex II electric actuators are the new standard of excellence for compact, power dense, servo driven devices. These linear actuators provide all the advantages of planetary roller screw design and fit within the space required for existing hydraulic or pneumatic cylinders. Now you can easily eliminate troublesome ball screw actuators and replace existing electric, hydraulic or pneumatic systems, without compromising on power.

Significantly Reduce Required Space and Operating Costs

These robust actuators deliver greater reliability and performance along with a small form factor. Since the servo drive and digital positioner are housed in a single, sealed package, space requirements are reduced. Moreover the integral design eliminates labor costs associated with mounting and wiring the panels. At the same time, you do away with the need for expensive, high maintenance servo cables and the associated long distance signal issues.

Other Advantages

  • Maximum power, precision, speed and repeatability in a compact package
  • Engineered for closed loop servo systems
  • IP54S environmental sealing standard (IP65S and IP66S options available)
  • 100% duty cycle for hundreds of millions of strokes
  • Hall effect incremental or absolute feedback
  • Sealed housing for extended life and reduced maintenance
  • Rockwell Automation Encompass Product Partner

 

Quick Data

Models: T2M75, T2M90, T2M115 (standard capacity actuators) – Legacy product
T2X75, T2X90, T2X115 (high capacity actuators)
Frame Sizes: 3, 3.5, 4.5 in (75, 90, 115 mm)
Stroke Length: 3, 4, 6, 10, 12, 14, 18 in (76, 102, 152, 254, 305, 356, 457 mm)
Linear Speed: up to 33.3 in/s (846 mm/s)
Continuous Thrust Capacity: up to 3225 lbf (14 kN)
Standards/Ratings: CE; UL 508 C Type 4 Enclosure; CSA 139; CSA Class I Division 2 Groups A, B, C, D; IP65S standard

Related Industries

Configuration Options

Tritex II AC Linear Actuator Configuration Options

T2X = Actuator Type
T2M75, T2M90, T2M115 (standard capacity actuators) – Legacy Product
T2X75, T2X90, T2X115 (high capacity actuators)

BBB = Frame Size
CC = Stroke Length
DD = Screw Lead (linear travel per screw revolution)
E = Connections
F = Mounting
G = Rod End
HH = Feedback Type

III-II = Motor Stator
Motor options are described with a 3-digit code. The first digit calls out the stack length, the second digit designates the rated bus voltage, and the third digit identifies the number of poles. Please refer to the mechanical/electrical specifications for motor torque and actuator rated force.

T2X075 Stators
(all 8 Pole and Class 180H)
T2X090 Stators
(all 8 Pole and Class 180H)
T2X115 Stators
(all 8 Pole and Class 180H)
138-40 = 1 stack, 230 VAC, 4000 rpm 138-40 = 1 stack, 230 VAC, 4000 rpm 138-30 = 1 stack, 230 VAC, 3000 rpm
238-30 = 2 stack, 230 VAC, 3000 rpm 238-40 = 2 stack, 230 VAC, 4000 rpm 238-20 = 2 stack, 230 VAC, 2000 rpm
338-20 = 3 stack, 230 VAC, 2000 rpm 338-30 = 2 stack, 230 VAC, 3000 rpm 238-15 = 2 stack, 230 VAC, 1500 rpm
(not available with 1-inch lead)

JJJ = Voltage
KKK = Option Board

Mechanical Options

AR = External Anti-rotate Assembly

This assembly restricts the actuator output rod from rotating when the load is not held by another method. Shorter actuators have a single anti-rotation mechanism; longer lengths have a mechanism on both sides.

L1, L2, L3 = Adjustable External Travel Switch(es)

External travel switches indicate travel to the controller and are adjustable for either the home or end position.*

RB = Rear Electric Brake

This is a rear, internal holding brake. The rear brake is spring activated and electrically released.

SR = Splined Main Rod

A ball spline shafting main rod with a ball spline nut that replaces the standard front seal and bushing assembly. This rod restricts rotation without the need for an external mechanism. The rod diameter will be the closest metric equivalent to our standard rod sizes. Since this option is NOT sealed, it is not suitable for environments in which contaminants may enter the actuator.

Note: Adding this option affects the overall length and mounting dimensions.

Standard Features

Tritex II AC Linear Actuator Standard Features
  • Analog and digital I/O
  • Built-in positioner
  • Internal terminals accessible through removable cover
  • Threaded ports for cable glands
  • M8 connector for RS485
  • M12 connector for EtherNet options
  • RS485 port, Modbus RTU (opto-isolated)
  • IP54S environmental sealing standard

* Some options are not available with every configuration. For options or specials not listed above or for extended temperature operation, please consult Exlar Applications Engineering.

IP Ratings for Exlar Actuators

Tritex II® AC Linear Actuator

T2X075
Performance Specifications
 Printable View

T2M/X075 Mechanical Specifications

  Units 0.1 Inch Lead
    1 Stack 2 Stack 3 Stack
Continuous Force lbf (N) 589 (2,620) 990 (4,404) NA
Peak Force lbf (N) 1,178 (5,240) 1,980 (8,808)*** NA
Max Speed in/sec (mm/sec) 6.67 (169) 5.00 (127) NA
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 5516 (24536) 5516 (24536) NA
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 3310 (14724) 3310 (14724) NA
  Units 0.2 Inch Lead
    1 Stack 2 Stack 3 Stack
Continuous Force lbf (N) 334 (1,486) 561 (2,496) 748 (3,327)
Peak Force lbf (N) 668 (2,971) 1,122 (4,991) 1,495 (6,650)
Max Speed in/sec (mm/sec) 13.33 (339) 10.00 (254) 6.67 (169)
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 5800 (25798) 5800 (25798) 5800 (25798)
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 3570 (15880) 3570 (15880) 3570 (15880)
  Units 0.5 Inch Lead
    1 Stack 2 Stack 3 Stack
Continuous Force lbf (N) 141 (627) 238 (1,059) 317 (1,410)
Peak Force lbf (N) 283 (1,259) 475 (2,113) 633 (2,816)
Max Speed in/sec (mm/sec) 33.33 (847) 25.00 (635) 16.67 (423)
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 4900 (21795) 4900 (21795) 4900 (21795)
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 3016 (13416) 3016 (13416) 3016 (13416)
  Units Universal Specifications
Speed RPM @ 240 VAC 4000 3000 2000
Drive Current @
Continuous Force
Amps 3.1 3.8 3.6
Available Stroke 
Lengths
in (mm) 3 (76), 6 (152), 10 (254), 12 (305), 14 (356), 18 (457)
Inertia 
(zero stroke)
lb-in-s^2/ Kg-m^2 0.002655 (0.000003000) 0.002829 (0.000003196) 0.003003 (0.0000033963)
Inertia Adder 
(per inch of stroke)
lb-in-s^2/in/ Kg-m^2/in 0.0001424 (0.0000001609) 0.0001424 (0.0000001609) 0.0001424 (0.0000001609)
Inertia Adder 
(per inch of stroke)
lb (kg) 10.8 (4.9) for 3 inch stroke, 1 stack.  Add 1.1 (0.5) per inch of stroke. Add 1.1 (0.5) per motor stack. 
Add .8 (0.4) for brake.
Operating 
Temperature 
Range*
-20C to 65C (-40˚C available, consult Exlar)
Continuous AC 
Input Current**
Amps 4.3 4 3.6

* Ratings based on 40˚C conditions.
** Continuous input current rating is defined by UL and CSA 
*** T2X peak force for 0.1 inch lead is 1980 lbf (8808 N). T2M peak force for 0.1 inch lead limited to 1620 lbf (7206 N).
**** Legacy Product

Data Curves
 Printable View

 


 

 

 

 


 

Estimated Life Time Curves
Ordering Guide
 Printable View

To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

 

 

Product Selection Guidelines

To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

AAA = Actuator Type

T2X = Tritex II Linear Actuator, high mechanical capacity

BBB = Actuator Frame Size

075 = 75 mm
090 = 90 mm
115 = 115 mm

CC = Stroke Length (nominal)

03 = 3 inch (76 mm) (T2X075, 090)
04= 4 inch (102 mm) (T2X115)
06 = 6 inch (150 mm)
10 = 10 inch (254 mm)
12 = 12 inch (305 mm)
18 = 18 inch (457 mm)

DD = Lead (linear travel per screw revolution)

01 = 0.1 inch (2.54 mm)
02 = 0.2 inch (5.08 mm)
05 = 0.5 inch (12.7 mm)
08 = 0.75 inch (19.05 mm) (T2X115 only)*

*0.75 lead not available above 12 inch stroke.

E = Connections

G = Standard straight threaded port with internal terminals, M20x1.5
N = NPT threaded port via adapter with Internal terminals, 1/2″ NPT
I = Interconnect style – Exlar std, M16/M23 style connector.

F = Mounting

C = Rear Clevis
D = Double Side Mount
E = Extended Tie Rod
F = Front Flange
G = Metric Rear Clevis
K = Metric Double Side Mount
M = Metric Extended Tie Rod
Q = Metric Side Trunnion
R = Rear Flange
T = Side Trunnion

G = Rod End

A = Male Metric Thread *
B = Female Metric Thread*
F = Female US Standard Thread *
M = Male US Standard Thread *

*Chrome-plated carbon steel. Threads not chrome-plated.

HH = Feedback Type

HD = Analog Hall Device
IE = Incremental Encoder, 8192 count resolution
AF = Absolute Feedback

III-II = Motor Stator, All 8 Pole

T2X075
138-40 = 1 stack, 230 VAC, 4000 rpm
238-30 = 2 stack, 230 VAC, 3000 rpm
338-20 = 3 stack, 230 VAC, 2000 rpm

T2X090
138-40 = 1 stack, 230 VAC, 4000 rpm
238-40 = 2 stack, 230 VAC, 4000 rpm
238-30 = 2 stack, 230 VAC, 3000 rpm*

T2X115
138-30 = 1 stack, 230 VAC, 3000 rpm
238-20 = 2 stack, 230 VAC, 2000 rpm
238-15 = 2 stack, 230 VAC, 1500 rpm (N/A with 0.1″ lead)

* N/A with 0.1″ lead.

JJJ = Voltage

230 = 115-230 VAC, single phase

KKK = Option Board

SIO = Standard I/O Interconnect
IA4 = SIO plus isolated 4-20mA Analog I/O
EIP = SIO plus Ethernet/IP with M12 connector
EIN = SIO plus Ethernet/IP without M12 connector*
PIO = SIO plus Profinet IO with M12 connector
PIN = SIO plus Profinet IO without M12 connector*
TCP = SIO plus Modbus TCP/IP with M12 connector
TCN – SIO plus Modbus TCP/IP without M12 connector*
COP = CANopen with M12 connector
CON = CANopen non-connectorized*

* Requires customer supplied Ethernet cable through I/O port for Class I Division 2 compliance only.

MM = Mechanical Options

AR = External Anti-rotate
L1/2/3 = External Limit Switches (2)
RB = Rear Brake
SR = Splined Main Rod (1)

  1. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator.
  2. Limit switch option requires AR option

 

For extended temperature operation consult factory for model number.

Consult Exlar when ordering splined stainless steel main rod.

T2X090
Performance Specifications
 Printable View

T2M/X090 Mechanical Specifications

  Units 0.1 Inch Lead
    1 Stack 2 Stack 2 Stack
Continuous Force lbf (N) 1,130 (5062) 1,488 (6619) NA
Peak Force lbf (N) 2,260 (10053) 2,700 (12010)*** NA
Max Speed in/sec (mm/sec) 6.67 (169) 6.67 (169) NA
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 5516 (24536) 5516 (24536) NA
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 3310 (14724) 3310 (14724) NA
  Units 0.2 Inch Lead
    1 Stack 2 Stack 2 Stack
Continuous Force lbf (N) 640 (2847) 843 (3750) 1,113 (4951)
Peak Force lbf (N) 1,281 (5698) 1,687 (7504) 2,225 (9897)
Max Speed in/sec (mm/sec) 13.33 (338) 13.33 (338) 10.00 (254)
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 5800 (25798) 5800 (25798) 5800 (25798)
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 3570 (15880) 3570 (15880) 3570 (15880)
  Units 0.5 Inch Lead
    1 Stack 2 Stack 2 Stack
Continuous Force lbf (N) 271 (1205) 357 (1588) 471 (2095)
Peak Force lbf (N) 542 (2410) 714 (3176) 942 (4190)
Max Speed in/sec (mm/sec) 33.33 (846) 33.33 (846) 25.00 (635)
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 4900 (21795) 4900 (21795) 4900 (21795)
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 3016 (13416) 3016 (13416) 3016 (13416)
  Units Universal Specifications
Speed RPM @ 240 VAC 4000 4000 3000
Drive Current @ 
Continuous Force
Amps 5.7 7.5 7.5
Available Stroke Lengths in (mm) 3 (76), 6 (152), 10 (254), 12 (305), 18 (457)
Inertia (zero stroke) lb-in-s^2/ Kg-m^2 0.002655 (0.000003000) 0.002829 (0.000003196) 0.003003 (0.0000033963)
Inertia Adder (per inch of stroke) lb-in-s^2/in/ Kg-m^2/in 0.0001424 (0.0000001609) 0.0001424 (0.0000001609) 0.0001424 (0.0000001609)
Approximate Weight lb (kg) 14 (6.35) for 3 inch stroke, 1 stack. Add 1 (0.5) per inch of stroke.Add 3 (1.4) per motor stack. Add 3 (1.4) for brake.
Operating Temperature Range* -20 to 65˚ C (-40˚C available, consult Exlar)
Continuous AC Input Current** Amps 6.3 6.3 6.3

* Ratings based on 25˚C conditions. 
** Continuous input current rating is defined by UL and CSA 
*** T2X peak force for 0.1 inch lead is 2700 lbf (12,010 N). T2M peak force for 0.1 inch lead limited to 1620 lbf (7206 N).
**** Legacy Product

Data Curves
Estimated Life Time Curves
Ordering Guide
 Printable View

To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

 

 

 

Product Selection Guidelines

To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

AAA = Actuator Type

T2X = Tritex II Linear Actuator, high mechanical capacity

BBB = Actuator Frame Size

075 = 75 mm
090 = 90 mm
115 = 115 mm

CC = Stroke Length (nominal)

03 = 3 inch (76 mm) (T2X075, 090)
04= 4 inch (102 mm) (T2X115)
06 = 6 inch (150 mm)
10 = 10 inch (254 mm)
12 = 12 inch (305 mm)
18 = 18 inch (457 mm)

DD = Lead (linear travel per screw revolution)

01 = 0.1 inch (2.54 mm)
02 = 0.2 inch (5.08 mm)
05 = 0.5 inch (12.7 mm)
08 = 0.75 inch (19.05 mm) (T2X115 only)*

*0.75 lead not available above 12 inch stroke.

E = Connections

G = Standard straight threaded port with internal terminals, M20x1.5
N = NPT threaded port via adapter with Internal terminals, 1/2″ NPT
I = Interconnect style – Exlar std, M16/M23 style connector.

F = Mounting

C = Rear Clevis
D = Double Side Mount
E = Extended Tie Rod
F = Front Flange
G = Metric Rear Clevis
K = Metric Double Side Mount
M = Metric Extended Tie Rod
Q = Metric Side Trunnion
R = Rear Flange
T = Side Trunnion

G = Rod End

A = Male Metric Thread *
B = Female Metric Thread*
F = Female US Standard Thread *
M = Male US Standard Thread *

*Chrome-plated carbon steel. Threads not chrome-plated.

HH = Feedback Type

HD = Analog Hall Device
IE = Incremental Encoder, 8192 count resolution
AF = Absolute Feedback

III-II = Motor Stator, All 8 Pole

T2X075
138-40 = 1 stack, 230 VAC, 4000 rpm
238-30 = 2 stack, 230 VAC, 3000 rpm
338-20 = 3 stack, 230 VAC, 2000 rpm

T2X090
138-40 = 1 stack, 230 VAC, 4000 rpm
238-40 = 2 stack, 230 VAC, 4000 rpm
238-30 = 2 stack, 230 VAC, 3000 rpm*

T2X115
138-30 = 1 stack, 230 VAC, 3000 rpm
238-20 = 2 stack, 230 VAC, 2000 rpm
238-15 = 2 stack, 230 VAC, 1500 rpm (N/A with 0.1″ lead)

* N/A with 0.1″ lead.

JJJ = Voltage

230 = 115-230 VAC, single phase

KKK = Option Board

SIO = Standard I/O Interconnect
IA4 = SIO plus isolated 4-20mA Analog I/O
EIP = SIO plus Ethernet/IP with M12 connector
EIN = SIO plus Ethernet/IP without M12 connector*
PIO = SIO plus Profinet IO with M12 connector
PIN = SIO plus Profinet IO without M12 connector*
TCP = SIO plus Modbus TCP/IP with M12 connector
TCN – SIO plus Modbus TCP/IP without M12 connector*
COP = CANopen with M12 connector
CON = CANopen non-connectorized*

* Requires customer supplied Ethernet cable through I/O port for Class I Division 2 compliance only.

MM = Mechanical Options

AR = External Anti-rotate
L1/2/3 = External Limit Switches (2)
RB = Rear Brake
SR = Splined Main Rod (1)

  1. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator.
  2. Limit switch option requires AR option

For extended temperature operation consult factory for model number.

Consult Exlar when ordering splined stainless steel main rod.

T2X115
Performance Specifications
 Printable View

T2M/X115 Mechanical Specifications

  Units 0.1 Inch Lead
    1 Stack 2 Stack 2 Stack
Continuous Force lbf (N) 2,060 (9,163) 3,224 (14,341) NA
Peak Force lbf (N) 4,120 (18,327) 5,400 (24,020)*** NA
Max Speed in/sec (mm/sec) 5.00 (127) 3.33 (84) NA
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 7900 (35141) 7900 (35141) NA
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 4736 (21067) 4736 (21067) NA
  Units 0.2 Inch Lead
    1 Stack 2 Stack 2 Stack
Continuous Force lbf (N) 1,177 (5,235) 1,843 (8,198) 2,380 (10,586)
Peak Force lbf (N) 2,354 (10,471) 3,685 (16,392) 4,760 (21,174)
Max Speed in/sec (mm/sec) 10.00 (254) 6.67 (169) 5.00 (127)
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 8300 (36920) 8300 (36920) 8300 (36920)
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 4890 (21751) 4890 (21751) 4890 (21751)
  Units 0.5 Inch Lead
    1 Stack 2 Stack 2 Stack
Continuous Force lbf (N) 530 (2,358) 829 (3,688) 1,071 (4,764)
Peak Force lbf (N) 1,059 (4711) 1,658 (7,375) 2,142 (9,528)
Max Speed in/sec (mm/sec) 25.00 (635) 16.67 (423) 12.50 (317)
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 7030 (31271) 7030 (31271) 7030 (31271)
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 4218 (18763) 4218 (18763) 4218 (18763)
  Units 0.75 Inch Lead
    1 Stack 2 Stack 2 Stack
Continuous Force lbf (N) 353 (1,570) 553 (2,460) 714 (3,176)
Peak Force lbf (N) 706 (3,140) 1,106 (4,920) 1,428 (6,352)
Max Speed in/sec (mm/sec) 37.5 (953) 25 (635) 17.75 (450)
T2X - C_a 
(Dynamic Load Rating)
lbf (N) 6335 (28179) 6335 (28179) 6335 (28179)
T2M**** - C_a 
(Dynamic Load Rating)
lbf (N) 3328 (14804) 3328 (14804) 3328 (14804)
  Units Universal Specifications
Speed RPM @ 240 VAC 3000 2000 1500
Drive Current @ 
Continuous Force
Amps 8.5 8.5 8.5
Available Stroke Lengths in (mm) 4 (102), 6 (152), 10 (254), 12 (305), 18 (457)
Inertia (zero stroke) lb-in-s2/ Kg-m2 0.01132 (0.000012790) 0.01232 (0.00001392) 0.01332 (0.00001505)
Inertia Adder 
(per inch of stroke)
lb-in-s2/in/ Kg-m2/in 0.0005640 (0.0000006372) 0.0005640 (0.0000006372) 0.0005640 (0.0000006372)
Approximate Weight lb (kg) 34 (15.5) for 6 inch stroke, 1 stack. Add 2 (1) per inch of stroke. Add 8 (4) per motor stack. Add 4 (2) for brake.
Operating Temperature Range* -20 to 65˚ C (-40˚C available, consult Exlar)  
Continuous AC Input Current** Amps 8.3 8.3 8.3

* Ratings based on 25˚C conditions. 
** Continuous input current rating is defined by UL and CSA 
*** T2X peak force for 0.1 inch lead is 5400 lbf (24,020 N). T2M peak force for 0.1 inch lead limited to 3966 lbf (17,642 N)
**** Legacy Product.

Data Curves
Estimated Life Time Curves
Ordering Guide
 Printable View

To order a product from Exlar, a unique model mask (identification number) is required. The model mask is a string of characters that identifies the model, size, and configuration alternatives.

 

 

Product Selection Guidelines

To facilitate your ordering process, feel free to print and complete this Exlar Application Worksheet, prior to contacting a Sales Representative in your area.

AAA = Actuator Type

T2X = Tritex II Linear Actuator, high mechanical capacity

BBB = Actuator Frame Size

075 = 75 mm
090 = 90 mm
115 = 115 mm

CC = Stroke Length (nominal)

03 = 3 inch (76 mm) (T2X075, 090)
04= 4 inch (102 mm) (T2X115)
06 = 6 inch (150 mm)
10 = 10 inch (254 mm)
12 = 12 inch (305 mm)
18 = 18 inch (457 mm)

DD = Lead (linear travel per screw revolution)

01 = 0.1 inch (2.54 mm)
02 = 0.2 inch (5.08 mm)
05 = 0.5 inch (12.7 mm)
08 = 0.75 inch (19.05 mm) (T2X115 only)*

*0.75 lead not available above 12 inch stroke.

E = Connections

G = Standard straight threaded port with internal terminals, M20x1.5
N = NPT threaded port via adapter with Internal terminals, 1/2″ NPT
I = Interconnect style – Exlar std, M16/M23 style connector.

F = Mounting

C = Rear Clevis
D = Double Side Mount
E = Extended Tie Rod
F = Front Flange
G = Metric Rear Clevis
K = Metric Double Side Mount
M = Metric Extended Tie Rod
Q = Metric Side Trunnion
R = Rear Flange
T = Side Trunnion

G = Rod End

A = Male Metric Thread *
B = Female Metric Thread*
F = Female US Standard Thread *
M = Male US Standard Thread *

*Chrome-plated carbon steel. Threads not chrome-plated.

HH = Feedback Type

HD = Analog Hall Device
IE = Incremental Encoder, 8192 count resolution
AF = Absolute Feedback

III-II = Motor Stator, All 8 Pole

T2X075
138-40 = 1 stack, 230 VAC, 4000 rpm
238-30 = 2 stack, 230 VAC, 3000 rpm
338-20 = 3 stack, 230 VAC, 2000 rpm

T2X090
138-40 = 1 stack, 230 VAC, 4000 rpm
238-40 = 2 stack, 230 VAC, 4000 rpm
238-30 = 2 stack, 230 VAC, 3000 rpm*

T2X115
138-30 = 1 stack, 230 VAC, 3000 rpm
238-20 = 2 stack, 230 VAC, 2000 rpm
238-15 = 2 stack, 230 VAC, 1500 rpm (N/A with 0.1″ lead)

* N/A with 0.1″ lead.

JJJ = Voltage

230 = 115-230 VAC, single phase

KKK = Option Board

SIO = Standard I/O Interconnect
IA4 = SIO plus isolated 4-20mA Analog I/O
EIP = SIO plus Ethernet/IP with M12 connector
EIN = SIO plus Ethernet/IP without M12 connector*
PIO = SIO plus Profinet IO with M12 connector
PIN = SIO plus Profinet IO without M12 connector*
TCP = SIO plus Modbus TCP/IP with M12 connector
TCN – SIO plus Modbus TCP/IP without M12 connector*
COP = CANopen with M12 connector
CON = CANopen non-connectorized*

* Requires customer supplied Ethernet cable through I/O port for Class I Division 2 compliance only.

MM = Mechanical Options

AR = External Anti-rotate
L1/2/3 = External Limit Switches (2)
RB = Rear Brake
SR = Splined Main Rod (1)

  1. This option is not sealed in any way. This option is not suitable for any environment in which contaminants come in contact with the actuator, and may enter the actuator.
  2. Limit switch option requires AR option

For extended temperature operation consult factory for model number.

Consult Exlar when ordering splined stainless steel main rod.

Resources

Certifications

See All Resource Material for the Tritex II and other products in our Resource Library

Login

Please log in or register to see the models and drawings.

Register

If you do not have a login, please proceed to the registration page

Register

If you currently have an Exlar website account and would like to delete it, please contact

CHA_Info@curtiss-wright.com

Privacy Notice

By giving us your contact information, you are giving consent to Curtiss-Wright / Exlar Automation to store your data and follow-up with you via email or phone.

At Curtiss-Wright, we promise to treat your data with respect and only share it with our representatives and distributors for the purpose outlined on the form. You can remove your request or information at any time by reaching out to our team at cha_info@curtisswright.com.

For further information on how we protect your information, please refer to our Privacy Notice.


Stay up to date

Get the latest Exlar product updates delivered directly to your inbox

You can change your mind at any time by clicking the unsubscribe link in the footer of any email you receive from us, or by contacting us at cha_info@curtisswright.com



Country *:
 Security code
 How we use this information